FUJIAIR Brief introduction of EVI compact heat pump:
1.This series of air source EVI heat pump is is specially designed for house heating in chilly climate areas, it can be applied to sanitary hot water for
bathroom or central heating for house where safe& stable working at temp -25 deg.C to 45deg.C.
2. Adopting the most advanced low- temperature Enhanced Vapors Injection compressor technology.
3. It has been further optimized to enable heat pumps to efficiently produce water temperature up to 60 deg.C during cold winter time.
This unit could be installed in outdoors, as floating support for compressor to reduce vibration at the most extent and noise insulation inside the cabinet
as well as noise jacket for compressor.
The compact design heat pump is built-in Copeland EVI scroll type compressor ,Stainless steel plate type and coaxial coil heat exchanger, Emerson
thermal expansion valve and Saginomiya four-way valve to ensure it work smoothly and efficiently.
This EVI heat pump comprises indoor unit and outdoor unit, which work together in safely& stably for house heating or sanitary hot water for bathroom in
chilly climate areas where its ambient temp at -25 deg.C to 45deg.C.
Adopting the most advanced low- temperature Enhanced Vapors Injection compressor technology.
The water system in the indoor unit which additionally built in circulation pump, expansion tank and thermostatic heating element to ensure better
anti-freezing protection and decrease the heat dissipate.
The EVI compressor is available to be built in the outdoor unit. On the other hand, outdoor unit includes Nylon fan ,evaporator, Emerson thermal expansion
valve and Saginomiya four-way valve to ensure it work smoothly and efficiently.
It has been further optimized to enable heat pumps to efficiently produce water temperature up to 60 deg.C, during cold winter time.
The following boundary conditions must be kept:
 The installation place should be selected in such a way that air intake and outlet is not hampered or obstructed leaves etc.
 There should be provided sufficient space for intake and outlet as well as for operation and maintenance.
 Air short-circuit must be avoided. The space necessary for intake and outlet must be always provided.
 Intake air must be completely free from aggressive substances like ammonia, sulphur, chlorine etc.
 The installation place should not be situated under living rooms or bedrooms because of sound emission and be placed at sufficient distance from the
neighboring building.
 It is not recommended to install the heat pump into wall niches(air short-circuit, sound echo)
 The heat pump must not be installed in a trough(in the terrain or building)
Air intake and outlet
Take particular account of the sound emissions. Local prescriptions must be observed.
Condensate pipeline
Condensate must be able to run off freely(frost protected drain.).The condensate drain must be provided on-site with an air-tight siphon of minimum height 100mm.
Wall lead through
Wall lead through for pipelines must be implemented and sealed by technicians.
Electric connections
 Electric connection cables must be short, connected flexibly and be mounted by technicians and according to local prescription.
 Where trace heating tapes for the condensate drain and the flow and return lines are used, they must be connected externally in accordance with applicable
regulations and additionally protected by a ground fault circuit interrupter.
Installation of Storage Hot Water Tank
? Storage hot water tank can be installed on the balcony, roof or ground with the outdoor unit. It can also be installed indoor.
? The tank must be vertically installed to the ground.
? The tank must stand with pads under its feet. (The thickness of the pad should be ?10cm).
? Heat Pump installation must be made easy.
? The tank shall not be hung on the wall.
? The framework for outdoor unit mounting should be secure and reliable installed.
See the Diagram (Only for reference)
Stop valve, Y-filter and check valve must be installed to the water feed pipe before water enters into the tank.
? Flexible pipe should be fixed to the relief valve for hot water, to release the pressure.
? Dirty water should be leaded to the floor drain through a flexible pipe, before that, stop valve must be installed to the pipe.